Documentation

Five Constraints in Series — LEDS Interrupts

Five Constraints in Series — LEDS Interrupts — 54.0% efficiency over 90 days, 7.00M bottles · ~70,000 pallets.

LEDS-Level track. The real failure modes, distributed across five machines. Now the bottleneck is a machine with a name and a reason.

At a glance

Experiment Single Run
Duration 90 days
System efficiency 54.0%
Production 7.00M bottles · ~70,000 pallets
Output unit bottles

What this model is

The five-machine split of Five Constraints in Series, but carrying the LEDS-level interrupt sets rather than one rolled-up Weibull per machine.

The line

Node Name
c0 Filler
c1 Capper
c2 Labeler
c3 Case Packer
c4 Palletizer

The interrupts

36 named failure modes, distributed across the line:

Machine Failure modes
Filler 7 — Filler, Silo to Weigh Hopper, Mix to Bulk Bin, Bulk to Filler Bin, and 3 more
Capper 12 — Micro Stop, Upper Plow Area, Capper, Compression, and 8 more
Labeler 3 — Labeler, Label Placement, Misalignment
Case Packer 2 — Photo Eye, Case Packer
Palletizer 12 — Hoist Area, Palletizer, Slat Sorter, Film_Break, and 8 more

Each carries its own time-to-failure and time-to-repair distribution, fitted per mode. Click a node in the sandbox to see them.

A bottleneck you can act on

The Constraint-Level version of this model named the Case Packer, roughly 0.8 points below four identical siblings — noise. Here the Capper is the binding stage by a wide margin, and one of its own failure modes accounts for more than half of its downtime.

That is a work order. The previous model could not produce one, not because it was built wrong but because averaging a machine's failure modes into a single Weibull destroys the distinction between them.

What the run produced

  • Bottleneck operating availability: 75.7%
  • System OEE: 54.0%
  • Bottleneck total downtime: 373.7 hours across 15,456 failure events
  • Mean time between failures: 4.5 min · Mean time to recover: 1.5 min
  • Throughput: 7,001,465 bottles
  • Blocked or starved: 619.4 hours (28.7%)

Top contributors (Capper only)

Rank Interrupt Downtime Share
1 Capper_Upper Plow Area 199.2 hrs 53.3%
2 Capper_Picker Tree Assembly 56.3 hrs 15.1%
3 Capper_Lower Plow Area 21.2 hrs 5.7%
4 Capper_Glue Station 21.1 hrs 5.7%
5 Capper_Carton Magazine 19.9 hrs 5.3%

The Upper Plow Area alone is 53% of Capper downtime. That's where the engineering investment goes. Downtime on other Constraints doesn't even place.

Where to go next

Add unit conversion: Two Constraints, Three Converters — LEDS.

Open it

This model ships with ReliaSim® and runs in the browser sandbox — no install required. Open 5 Constraints in the sandbox.

Every recorded figure on this page is the published result for the model as it ships.